After adding the vision system to the RSLogix project, the L5X rung import file can be used to create structured data for the connection. For more information, see EtherNet/IP Object Model and Input/Output Assembly Objects - In-Sight 4.x.x Firmware. For more information, see EtherNet/IP Object Model and Input/Output Assembly Objects - In-Sight 5.x.x and Later Firmware.įor In-Sight vision systems running In-Sight 4.x.x firmware, the Assembly Objects section defines the Assembly Instance that should be configured. For In-Sight vision systems running In-Sight 5.x.x and later firmware, the Assembly Objects section defines the Assembly Instance that should be configured.The In-Sight vision system's name and IP address.In the New Module dialog, enter the following:.From the Select Module Type dialog in the Catalog tab, select the Communication Module Type Category Filter, Allen-Bradley as the Module Type Vendor Filter, select ETHERNET-MODULE (Generic Ethernet Module) and press the Create button.Under the I/O Configuration node, select the Ethernet Node under the Ethernet Module, right-click on the icon and select New Module from the menu. The PLC must be Offline to add connections in RSLogix 5000.Īdd a connection to your Ethernet Communications Card.